Output Power

Continuous Power
Surge Power
No Load Power
Output Voltage
Output Current
Weight LBS.
125 Watt
150 Watts
5 Watts
100 +/- 6%
1.2
2
125 Watt
150 Watts
5 Watts
120 +/- 6%
1.1
2
250 Watt**
300 Watts
6 Watts
100 +/- 6%
2.5
5
250 Watt**
300 Watts
6 Watts
120 +/- 6%
2.1
5
250 Watt**
300 Watts
7 Watts
230 +/- 6%
1.1
5
600 Watt**
1100 Watts
8 Watts
100 +/- 6%
6.0
6.5
600 Watt**
1100 Watts
8 Watts
120 +/- 6%
5.1
6.5
600 Watt**
1100 Watts
9 Watts
230 +/- 6%
2.7
6.5
1100 Watt**
2200 Watts
20 Watts*
100 +/- 6%
11.0
10
1100 Watt**
2200 Watts
20 Watts*
120 +/- 6%
9.5
10
1100 Watt**
2200 Watts
20 Watts*
230 +/- 6%
4.8
10
2000 Watt
4000 Watts
12 Watts*
120 +/- 2%
17.0
15
*10W with X2 option
**remote switchable
Input Power
Model Voltage
Minimum (Typical)**
System (Typical)
Maximum (Typical)**
Typical Efficiency @ Full Power
Peak Efficiency @ 1/3 Power
***12Vdc
10.4/10.6Vdc*
13.8Vdc
16.5Vdc
85%
87%
24Vdc
19/21Vdc*
27.6Vdc
33Vdc
87%
89%
32Vdc
26.5/28Vdc*
36.8Vdc
44Vdc
88%
90%
48Vdc
41.5/42.5Vdc*
55.2Vdc
62Vdc
87%
89%
66Vdc
57.5/58.5Vdc*
75.9Vdc
91.1Vdc
88%
90%
108Vdc
94/95Vdc*
125Vdc
149Vdc
87%
90%
*Indicates typical cut-off voltage/warning buzzer voltage
** +/- 3% ***Output Power derated for XPX
General
Conditions
Minimum
Typical
Maximum
Waveform
-
Sinusoidal
-
Voltage Output
- 5%
Nominal
+5%
Line Regulation
-
0.1%
0.5%
Load Regulation
-
0.5%
1%
Distortion
-
1.5%
2%
Frequency
-0.1%
Nominal
+0.1%
Mechanical

Case size (WxHxD)

125W case size= 4.93“ x 2.00” x 6.80” (2 lbs) | 125 Watt drawing

250W case size= 5.23“ x 2.77” x 10.38” (5 lbs) | 250 Watt Drawing

600W case size= 7.70" x 3.60" x 11.77" (6.5 lbs) | 600 Watt Drawing

1100W case size= 7.70“ x 3.60” x 14.77” (10 lbs) | 1100 Watt Drawing

2000W case size= 7.70“ x 3.60” x 14.77” (10 lbs) | 2000 Watt Drawing

Protection Cicuitry

Over Voltage*: Shut off at maximum input voltage, per input conditions. Automatic reset upon fault correction.

Under Voltage*: Shut off at minimum input voltage, per input conditions

Thermal*: 105 C internal temperature. Warning buzz 5 C before shut off

Output Short: Unit shuts off (manual reset)

*Automatically reset
Environmental

Temperature: -25 to 30 C full power derated above 30 C.

Humidity: 5 to 95% non condensing

Altitude: -200 to 10k feet full power, derated above 10k

Audible Noise: Less than 45dbA

Cooling: 600W/1100W Thermo- statically controlled forced air. 125W/250W convection cooled.

Finish: Painted aluminum

Warranty: Full year parts labor View the > Limited Warranty