The
EXELTECH frequency
converter is operated by simply plugging in the supplied cord to
the power input, connecting the load to the output plug
provided, and turning the unit on.
Specifications are listed on the product label regarding maximum
input and output voltages and currents.
The unit is protected against thermal and electrical overload.
Electrical overloads will cause the AC voltage to collapse as
the inverter limits output current. When the overload is
removed, output voltage will return to normal. If the output is
short circuited the unit will latch itself off, turning the
front LED red. This requires the power switch to be cycled to
reset the condition (turn the unit off then back on again).
Should the unit be thermally overloaded, too much load at too
high a temperature, it will shut off, leaving the fan running.
When the internal temperature cools sufficiently the unit will
turn itself back on.
When the unit is operating normally, the LED on the front will